Skip to main content

Create resin type

Create a resin grade definition so inspectors can identify which raw-material readings to supply and which carbon-black range belongs to the grade. Use the agreed material specification as your source; the numbers you enter are specific to that resin.

Open Quality Control → Configuration → Resin Specifications.

Prepare the specification​

Have the resin name, required inspection fields, and minimum and maximum carbon-black percentages ready. Required Inspection Fields can include the given and tested ash, density, and melt values, as well as dimensional and carbon-black readings. Select the fields your inspection actually requires.

Raw-material pass processing checks the selected resin's required fields for missing or zero values. A populated value is a completeness check; it does not by itself establish that the material is within its acceptance limits.

Create the resin type​

  1. Select Create Resin Type.
  2. Enter Resin Name and Required Inspection Fields.
  3. Enter Min Carbon Black Content (%) and Max Carbon Black Content (%) from the specification. Read the pair together to catch an accidental reversal or wrong grade; this is your check before saving.
  4. Select Register Resin Type.

Verify the definition​

Find the resin in Resin Specifications and reopen Update. Compare its name, selected fields, and both percentages with the intended specification. Saving a resin definition does not record test readings or complete an inspection.

FAQ​

Business questions​

When should I create a resin type?​

Create a distinct definition for a resin grade with its own inspection requirements.

How are required readings different from acceptance limits?​

Required Inspection Fields identifies readings that must be present for the selected resin during raw-material pass processing. Presence and nonzero validation do not establish acceptable test results.

Does saving a resin specification release material?​

Saving records the specification. The inspection still needs its test data and a separate inspection decision.

Technical questions​

Which values do I enter?​

Enter Resin Name, the selected Required Inspection Fields, and minimum and maximum carbon-black percentages.

Why can a raw-material pass reject an entered zero?​

When a resin is selected, its configured required fields are checked for missing or zero values. Check the recorded reading and the selected resin definition rather than substituting an invented measurement.

Where do I check that the specification was saved?​

Find the resin in Resin Specifications and reopen Update. Compare the name, field selections, and both carbon-black values with your specification.