Create finished goods control point
Create a reusable inspection definition for finished goods checks. A control point describes the work to inspect; an inspection records what happened in a particular case.
Open Quality Control → Configuration → QC Points - Finished Goods.
Prepare the definition
Have the material or product selection and the agreed inspection method and frequency ready. Use a name that distinguishes this definition from other checks at the same stage.
Add the item rows for the finished products this point describes.
Choose Measurement, Voltage, or Visual for Inspection Type. Use Required Tests to identify the readings needed, such as Outside Diameter, Density, or Min Wall Thickness. These are selected tests, not entered test results.
Inspect All Units covers every unit. Random Sampling describes sampling without a fixed schedule. Periodic Checks describes checks at fixed intervals. Choose the frequency agreed for this material or product; this form does not specify a sample size or an interval length.
Create the control point
- Select Create new quality control point.
- Enter Quality Point Name, then add the item rows using the selections described above.
- Set the inspection choices to the agreed definition. Add Notes for context the next inspector needs.
- Select Create Control Point.
Check the saved definition
Find the saved point in QC Points - Finished Goods, open Update, and compare the name, products and required tests, method, frequency, and notes with what you intended to save. Check Status separately from the definition.
Saving this definition records configuration. It does not record a measurement or a pass/fail decision on an inspection. Keep inspection results with the relevant inspection record.
FAQ
Business questions
When should I create a finished goods control point?
Create a new point when you need a distinct reusable inspection definition.
How do I choose what this finished goods point covers?
Add the item rows for the finished products this point describes.
Does creating the point finish an inspection?
No. This action saves the control-point definition. Measurements and inspection decisions belong to individual inspection records.
Technical questions
How do I choose Control Frequency?
Inspect All Units covers every unit. Random Sampling describes sampling without a fixed schedule. Periodic Checks describes checks at fixed intervals. Choose the frequency agreed for this material or product; this form does not specify a sample size or an interval length.
Which inspection inputs can I configure?
Choose Measurement, Voltage, or Visual for Inspection Type. Use Required Tests to identify the readings needed, such as Outside Diameter, Density, or Min Wall Thickness. These are selected tests, not entered test results.
How do I verify my saved changes?
Reopen the point with Update and compare its name, scope, method, frequency, and notes. Also compare Required Tests.